Your Quality Finishing Systems Pre-Treatment Washer will be designed and fabricated based on the following factors:
- Conveyor line speed
- Part geometry
- Chemical supplier input
- Paint supplier input
Standard features on all of our washers include:
- 7-gauge 304L 2B stainless steel tanks, tunnel, and drain decks, all with weld passivation
- Sloped tank floors and drain decks for cleanliness and easier drainage
- 14-gauge stainless steel tank access lids with “vapor sealing” design
- Electronic water level controls for each stage
- Water fill manifolds and controls
- Dual stainless steel pump screens with sludge dams for each stage
- Overflow and drain pipe with valve on each tank
- Powered modulating immersion tube burners with filtered combustion air
- Serpentine burner tubes are 304L stainless steel schedule 40 first pass, the remainder of the tube is schedule 10 and include weld passivation
- Factory assembled gas manifolds built to NFPA design, with FM components
- Valve proof of closure switch and burner low fire start switch
- Galvanized steel burner tube exhaust stacks
- Personnel guards around burner stacks up to approximately 9’ from the floor
- Pressure gauges on all pump discharge headers
- Temperature gauges on all heated stage pump discharge headers
- Pump construction: stainless steel wetted, stainless steel fitted pumps, or mild steel
- Premium efficiency TEFC pump motors
- Schedule 80 CPVC headers and risers, Cam-Lock quick disconnect fittings on headers and risers
- Snap-on adjustable spray nozzles
- Bottom feed header orientation
- 14-gauge 304L 2B stainless steel tunnel walls welded 100%
- Tunnel access doors located between stages
- 304L 2B stainless steel conveyor shroud
- 18” wide fiberglass full length grating catwalk
- Entry and exit vestibule exhaust fans (epoxy coated), with premium efficiency TEFC motor
- 304L 2B stainless steel vestibule exhaust stacks with one offset each and flapper stack cap
Options Include:
- Gasketed tank access panels are secured to the external wall by studs; the bottom of the access opening is flush with the tank floor.
- High velocity blow-off system
- Washer access platforms and lighting at the doors between all stages
- Water counterflow makeup systems
- Water counterflow rinse systems
- Misting risers
- Final rinse halos
- RO systems
- Insulated washer tanks
- HRS or 316L stainless steel construction
- VFD control for pump motors
- Filtration
- Top feed headers
- Installation, startup, and training